28
Acknowledgement and Abort Options
Abort options
Occasionally, you may trigger your alarm by accident and cause the SD2 to
send an unwanted call. When this happens the unit can be aborted. When
a call is aborted the SD2 immediately hangs-up and returns to its normal
standby mode.
The trigger inputs can be programmed to one of the following options:
None
Trigger inputs cannot be aborted, (default).
Passcode Only
The selected trigger input can only be aborted by entering the operator’s
passcode into the SD2.
Code or Restore
The selected trigger input can be aborted by either entering the operator’s
passcode into the SD2 or by restoring the trigger input to its normal
healthy condition.
Restore Only
The selected trigger input can only be aborted by restoring the trigger
input to its normal healthy condition.
Edit Call Abort Options:
From the main menu press ¬and ¦ or 5 to select the Acknowledge &
Abort Options:
1. Press [ to select: