Connection terminals on the SD2 are described as either “Safety Extra Low
Voltage” circuits (SELV) or “Telecommunications Network Voltage” circuits
(TNV).
It is important that the TNV connections are only connected to the PSTN,
and SELV circuits are only connected to designated SELV circuits.
Interconnection circuits should be such that the equipment continues to
comply with the requirements of 4.2 of EN 41003 for TNV circuits and 2.3
of EN 60950 for SELV circuits, after making connections between circuits.
Connections to the control panel
Before making any connection to the SD2 isolate ALL power from the
control panel (AC mains and battery). Do not continue if there is power
still present on the control panel.
+12V & 0V
Connect these terminals to the 12V auxiliary power supply of the alarm
control panel.
Trigger 1 - 4
Connect these terminals to the relevant outputs on the alarm control panel.
When an alarm panel triggers an input, the SD2 initiates the calling
sequence and plays the relevant speech and/or text message. The
diagrams below show the various wiring options for the trigger inputs:
Trigger inputs programmed for +ve operation
TAMPER
TRIG
A
B
C
D
OP1
OP2
12V 0V
Trigger
inputs
To 12v
Auxiliary
supply
N.O
Loop
TAMPER
TRIG
A
B
C
D
OP1
OP2
12V 0V
Trigger
inputs
To 12v
Auxiliary
supply
N.C
Loop